![]() Set the communication Settings to Custom, Baud (115200), Format (7,2,E), Mode (Host Link) and Unit Number to (0). Select the Serial Port 1 or Port 2 tab where CP1W-CIF01 is mounted. Start CX-Programmer, create a new program and select a CP1L. ![]() Select the ‘COM1 Settings’ tab and set the Host Link Communication settings to Type (RS232), Baud Rate (115200), Data Bit (7), Parity Check (Even) and Stop Bit to (2).ĭouble click on the CP1 in the “Project Structure Window” to open the PLC Attribute. In order to avoid malfunctions caused by interferences, shield the cables properly.ĭouble click on the NB in the “Project Structure Window” to open the HMI Attribute. NB pin 9 (SG) to CP1L (CP1W-CIF01) pin 9 (SG)ĬP1W-CIF01 Bridge between pin 4 (RS) and pin 5 (CS) NB pin 3 (RD) to CP1L (CP1W-CIF01) pin 2 (SD) NB pin 2 (SD) to CP1L (CP1W-CIF01) pin 3 (RD) Connect with the Serial connection line the CP1L to the COM1 port of the NB. ![]() ![]() Start NB-designer, create a new program, drag and drop the NB and the CP1L on the “Project Structure Window”. NB with CP1L through COM1/RS232 (Host Link) This article is related to the article NB HMI and Connecting Peripheral Devices and explains how connection can be established with a CP1L and a CP1W-CIF01 using Host Link (RS232C).
0 Comments
Leave a Reply. |
AuthorWrite something about yourself. No need to be fancy, just an overview. ArchivesCategories |